Technical Parameters:
1. Permanent magnet DC motor voltage: 12/24VDC
2. The maximum push / self-locking force: 90KG/230KG
3. Standard stroke: S = (50, 100, 150, 600) mm, can be customized according to customer requirements.
4. The shortest installation distance (the inner tube is fully retracted to the center of the bottom plate): L = S (stroke) + 140mm; the inner tube is fully extended to the center of the bottom plate = 2*S (stroke) +140mm
5. No-load speed: up to 40mm/s
6. Rated load rate: 5mm/s (90KG)-40mm/s (10KG)
7. Ambient temperature: -26°C to 65°C
8. Standard protection level: IP54
9. Built-in limit switch, potentiometer
10. Low noise design, noise level below 50dB
11. Can be equipped with wire or wireless remote control